No power? Follow the checks in order
A step-by-step guide for when the power goes off or a safety switch keeps tripping. Print it and keep it near your switchboard.

Before you start
- Only operate accessible switches on a dry, undamaged switchboard. Never remove covers or touch wiring.
- Water, sparks, burning smells or visible damage? Stop, keep clear and get help.
- Electric shock or tingle? Do not touch the switchboard. Call Western Power on 13 13 51 and seek medical advice after a shock.
- Fire or immediate danger: call 000.
-
Has a switch tripped?

A tripped RCD (safety switch) in the OFF position. 
An RCBO switched to OFF. Look for an RCD, RCBO or circuit breaker at OFF or in the middle. RCDs and RCBOs have a TEST or T button.
No switch tripped Check Western Power’s power outage map. No listed outage? In strata, ask whether neighbours also have power. If other units are out, contact your strata manager first. No area or complex outage? Contact us for advice.Yes, a switch has tripped Continue to step 2. Unsure which switch it is? Contact us before going further. -
Was any work being done?
Did it trip while someone was drilling, hammering nails, fitting screws or doing other work?
Cable damage is possible Stop the work. Do not reset the circuit. If safe, leave the affected circuit and RCD OFF and contact a licensed electrician.No work, or no cable damage suspected? Continue to step 3.
-
Try an initial reset
If safe, switch off and unplug the appliance being used when it tripped. Move the tripped switch fully to OFF, then back to ON once.
It stays on Leave any suspect appliance out of use until it’s checked. If tripping happens again, book fault finding, even if a reset restores power.It trips again Continue only if you can identify the correct labelled switches. Never force a switch or keep retrying a circuit that trips. -
Find the affected circuit
Single RCBO or circuit breaker? Its label identifies the circuit. Switch it fully OFF and go to step 5.For one RCD protecting several circuits:
- Switch the RCD OFF, then switch OFF all circuit breakers protected by that RCD.
- With those breakers OFF, reset the RCD once. If it will not stay ON, leave it OFF and contact us.
- If it stays ON, switch the protected circuit breakers ON one at a time.
- If the RCD trips, switch the last breaker OFF. Check that circuit in step 5. Do not retry it until appliances have been disconnected.
All breakers stay on? The fault may be intermittent. Arrange an inspection if it happens again.Old fuses or unclear circuit labels? Stop and contact us. Do not remove or replace fuses.
-
Check the appliances
Leave the affected circuit OFF. Switch off and unplug all appliances on that circuit, including fridges, freezers, chargers, powerboards and outdoor equipment.
Turn off lights and hardwired appliances on that circuit using their normal switches only. Do not open fittings or disconnect wiring.
Reset the RCD if separate, then turn the affected circuit breaker or RCBO back ON once.
It still trips with items off or unplugged Leave the affected circuit OFF and contact a licensed electrician. The fault may be in the wiring, a fixed appliance or the protective device.It stays on Continue to step 6. -
Reconnect one item at a time
Plug in and switch on one appliance at a time. Turn on lights and hardwired appliances individually too. Check for tripping between each item.
It trips after an item is reconnected The last item may be the cause. Switch it off and unplug it if safe. Leave it out of use until it’s checked, repaired or replaced. Contact us if you’re unsure.Everything stays on Monitor it. Repeated or unexplained tripping still needs investigation by a licensed electrician.
Know your switches

RCD
Residual current device: a safety switch that detects current leaking to earth. Often protects several circuits, and has a T (test) button.

RCBO
An RCD and circuit breaker combined in one device, usually protecting one circuit.

MCB or CB
Miniature circuit breaker or circuit breaker: protects against overload and short circuits. It doesn’t have a test button.


Main switch
Controls the electricity supply. It is different from an individual circuit breaker. Single phase is usually one switch (left); three phase is usually three switches joined together (right).

Fuse
Older circuit protection, like these ceramic fuses. A fuse can’t be simply reset like a circuit breaker; removal and replacement is carried out by an electrician. We recommend converting to circuit breakers or RCBOs, or a switchboard upgrade.